我国输电线路基础工程现状及存在的问题我国输电线路基础工程现状及存在的问题程永锋,邵晓岩,朱全军(国家电力公司电力建设研究所,北京市,101055)[摘要]根据我国现有的技术规范,架空输电线路基础设计仍沿用总安全系数法,设计的基础尺寸比国外大,设计较为保守,基础施工费用比国外高出很多,在国外竞标中,处于不利地位。为此,在调研的基础上,比较全面、深刻地分析了架空输电线路地基基础工程现状及存在的问题。[关键词]架空输电线路基础工程现状存在问题中图分类号:TU753文献标识码:A文章编号:1010-7329(2002)03-0032-03CurrentSituationofFoundationWorksandExistingProblemsforTransmissionLinesinChinaChengYongfeng,ShaoXiaoyan,ZhuQuanjun(ElectricPowerConstructionResearchInstitute,StatePowerCorporation,Beijing,101055)[Abstract]AccordingtothepresenttechnicalspecificationinChinathedesignoffoundationofoverheadtransmissionlinesstillusesthegeneralsafetyfactor,whilethedesignedsizeofthefoundationislargerthanthatoftheforeign.Thedesignisrela2tivelyconservativeandexpenseforconstructionofthefoundationismuchhigherthantheforeign.SoduringtheforeigntendercompetitionChinaisinanunfavorableposition.Forthispurposethepaperhasanalyzeddeeplythecurrentengineeringsituationofgroundfoundationandexistingproblemsoftheoverheadtransmissionlinesinawholebasedontheinvestigation.[Keywords]overheadtransmissionline;foundationworks;currentsituation;existingproblem杆塔基础作为输电线路的重要组成部分,它的造价、工期和劳动消耗量在整个线路工程中占很大比重。据有关资料统计:输电线路基础工程施工工期约占整个工期的一半,运输量约占整个工程的60%,费用约占整个工程的15%~35%。基础选型、设计及施工的优劣严重影响着线路工程的建设。根据我国现有的技术规范,铁塔设计和国外相比,较为合理和成熟,而基础设计的尺寸比国外大,设计较为保守[1,2],基础施工费用比国外要高出很多。同时,基础过大,若采用大面积开挖,势必会造成大面积植被的破坏和水土的流失。因此有必要加强对输电线路基础的研究,降低混凝土和钢筋的用量,减小土石方的开挖量,从而降低基础造价,节省资源,同时也减小对植被的破坏,加强环境保护,取得较好的经济效益和社会效益,实现可持续发展。但是目前我国尚未系统地开展新的基础型式的试验、测试和分析研究,杆塔基础已成为输电线路建设中十分薄弱的环节,地基处理及其基础型式选择与设计优化是当前输电线路工程迫切需要解决的重大课题。1我国输电线路基础工程现状我国幅员辽阔,各个地区的地质条件相差很大,所采用的输电线路基础形式也较为多样。其中西北地区主要为黄土地基,部分为沙漠及岩石地基。黄土地基使用的基础形式主要有刚性台阶式基础和插入式基础,部分软弱地基则主要采用钻孔灌注桩。西北地区黄土具有湿陷性,常采用二灰换添法,石灰和素土的比例一般采用2∶8或3∶7,对重点塔位的地基重点处理。沙漠地区地基抗剪强度低,比普通基础要多埋深lm。山区的岩石地基使用的基础形式收稿日期:2001-11-06作者简介:程永锋(1969~),男,博士,主要从事发电厂、变电所、输电线路地基基础工程、地基处理、岩土边坡加固、基坑工程的科研、设计和工程管理工作。?23?第23卷第3期2002年3月电力建设ElectricPowerConstructionVol.23No.3Mar,2002本文来源:网络收集与整理,如有侵权,请联系作者删除,谢谢!